bossmanfilter@gmail.com +91 94483 67319

Knockout drum

Flare knockout drums (FS) are used in flare systems for associated petroleum gas treatment intended for combustion in flare units at gas-producing, gas-condensate and gas processing enterprises,from drip moisture, mechanical impurities and other suspended particles.Knock out drums are used to slow down gasses and allow liquids to fall out of the gas stream. Knock out drums can be installed either in the waste gas header, or in the flare stack base itself.Knock out drums can be configured in either a horizontal, or vertical arrangement. When horizontal, a knock out drum will be constructed with one gas stream inlet, and two outlets, which can then be joined with a manifold. Another configuration that can be used is one inlet with a much larger outlet.

Knockout drum

Specifications

Product Name Flare Knockout Drums
Brand Bossmanfilter
operating product
  • Non-corrosive natural gas (H2S content up to 0.001%)
  • Highly corrosive natural gas(CO2 content up to 70%)
  • hydrocarbon condensate
  • water
  • corrosion inhibitor
  • methanol
volume, m3 4.0-200.0
vessel type according ASME Section VIII Div. 1
product capacity, nm3/day up to 2200
pressure, MPa up to 4.0
Shell temperature,℃ up to +150
operating product temperature,℃ from -50 to +50
operating temperature,℃ from -60 to +50
purification efficiency, % 99
Material SA516 Grade 70 carbon steel, and the forge fittings are fabricated from SA105 carbon steel
structural design
  • with thermal treatment/without
  • with heat insulation/without
  • with heat-exchanging device/without
seismicity, points up to 6
projected service life, years 12